Schematic of the stairs
General view of the
Drawing stage
Recommendations
Deviation from the formula for 16.7%
We recommend reducing the number of steps more on 2The lack of depth of step: 230 mm
Recommend increasing the protrusion F on 50 mmConvenient staircase inclination 36.9°
An Inconvenient stair
Initial data
Lift 1500 mm
The length of the ladder in terms of 2000 mm
Number of steps 10
The thickness of the treads 50 mm
Tread Overhang 30 mm
Platform length 500 mm
Thickness pad 100 mm
Extra thickness 50 mm
The thickness of the treads 60 mm
Stringer
The length of the stringer 2500 mm
The angle of the stairs 36.9°
Step size
Step height 150 mm
Depth steps 230 mm
Volume of concrete
Volume site 0.04 cubic meters
Volume of one stage 0.012 cubic meters
Volume of all levels 0.12 cubic meters
Amount of additional thickness 0.1 cubic meters
Armature
Number of valves 30 pieces
Number of valves 24 m
Weight bars 9.47 kg
Total volume of concrete 0.26 cubic meters
© www.zhitov.com